Termination Extraction Tools |
 |
|
Order the ET-X75A for removing a damaged termination from its mounting hole when the Probe and Optional Spacer Plates are removed. Order the ET-X75A-EXT for removing a damaged termination from its mounting hole when the Probe and optional Spacer Plates are installed.
|
| |
|
|
| |
|
Termination Insertion Tools |
 |
|
Order the IT-X75A-FLUSH or IT-X75A SET .XXX (.000/.140 [0.00/3.56]) tools to install X75-25/40 terminations.
|
| |
|
|
| |
|
Pin Gauge Tools |
 |
|
Mounting
holes in AT7000, G10/FR4
or similar materials for
the Probe Plate should be
gauged at .0545/.0555 [1.384/1.409]
diameter using PG-X75A-P pin
gauge. Mouning holes in
AT7000, G10/FR4 or similar
materials for the Back Plate
(wired) should be gauged
at .0515/.0525 [1.308/1.333]
diameter using PG-X75A-T pin
gauge. Mounting holes in
AT7000, G10/FR4 or similar
materials for the Back
Plate (wireless) should
be gauged at .038/.039 [0.965/0.990]
diameter using PG-X50T pin
gauge.
|
| |
|
|
| |
|
Probe Installation Tools |
 |
|
Use PT100/75 to install X75-25 or X75-40 probes.
|
| |
|
|
| |
|
X Probe Extraction Tool |
 |
|
Order the PEX75 for removing damaged X Probe tubes without damaging the fixture. |
| |
|
|
| |
|
Indicator Probes |
 |
|
Use IPX75-4010 or IPX75-4040 to measure probe stroke in a test fixture (plunger remains at deflected position). |
All specifications subject to change without notice. All dimensions are in inches [mm].
All spring forces in ounces [gms].